Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 155 items found.

  • Bore Gauge

    BG10 - Aeronautical & General Instruments Ltd.

    The BG10 Gun Barrel Bore Gauge System is an electro-mechanical measuring device that was originally introduced into service by the RAF for the high-speed measurement of aircraft cannons, to ensure minimum operational aircraft turnaround time. Measurements are taken at 16 pre-determined positions along each bore, which are then compared to pre-stored warning and rejection criteria. The actual measurements taken are displayed to the Operator on an LCD display and the measurements stored for future reference. The system will automatically provide a visual indication on the Hand Held Unit whether the barrel was acceptable, close to tolerance or rejected – all this to be undertaken in less than five minutes!

  • PXIe-6614, 5 V, 8-Channel, Precision Reference PXI Counter/Timer Module

    782353-01 - NI

    PXIe, 5 V, 8-Channel, Precision Reference PXI Counter/Timer Module—The PXIe‑6614 is a high-precision counter/timer module that performs encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features eight counter/timers, digital debouncing filters, and TTL/CMOS‑compatible digital I/O. The PXIe‑6614 offers industrially rugged features for a wide array of applications such as automotive/aerospace, industrial/motion control, and manufacturing test. Measurements are highly accurate and precise over longer periods of time because of the oven‑controlled crystal oscillator (OCXO) in the module.

  • Balance Thermocouple Power Sensor, DC To 50 GHz

    N8487S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Balance Thermocouple Power Sensor, DC To 18 GHz

    N8481S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Portable Calibration Baths

    6109A / 7109A - Fluke Calibration

    The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.

  • The Mag Lead

    136 - Electronic Specialties Inc.

    *Mag Lead features a magnetic disconnect near the test probe end. *Just disconnect the test probe and you can “stick” to any metallic ground or test point. *Quit fumbling with alligator clips that fall off - Mag Lead’s powerfull magnet will hold tight! *This is a time saving tool - if you don’t have to walk to your tool box to retrieve your alligator clips, even on just half the occasions, then you’ve saved time. *Very helpful for automotive reference points and troubleshooting. *Can eliminate the need to hold probes while checking or monitoring a signal. *Two high power, low resistance magnets hold the probe to the lead. *Fits almost all Digital Multimeters and can be used with hand-held scopes too. *Get the Mag Lead, it stays put and won’t fall off, like alligator clips do!

  • ARINC 429 Test & Simulation Instrument for PXI

    PXI-C429 - Avionics Interface Technologies

    4, 8, 16, or 32 Software Programmable Tx/Rx ChannelsProgrammable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection • Data capture filtering, 100% bus recording, and physical bus replay - Rate-oriented Label Transmission - Label Selective Trigger for Capture/Filtering - IRIG-B time code encoder/decoder with free-wheeling mode - Time Synchronization to PXI 10MHz reference clock - Application Interface supporting C/C++, C# and VB.NET Development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Safety Laser Scanner Type 3

    SD3-A1 - Panasonic Industrial Devices Sales Company of America

    The Panasonic SD3 Safety Laser Scanner is a cost-effective alternative for guarding danger zones. It can be used flexibly in confined spaces and for areas where the danger zone changes.The SD3 can monitor an area within an angle of up to 190° and divides it into 2 zones: a warning zone within a radius of 15m, and a protection zone within a radius of 4m. The contours of these zones can be configured precisely for any application. Up to eight zone patterns can be set and activated at any given time even during operation.The reference boundary function memorizes the position of stationary objects and establishes a virtual boundary. It also monitors beam alignment after installation and issues an alarm if a beam becomes misaligned.

  • Active Filter

    J2190A - PICOTEST Corp.

    The J2190A active filter presents a high impedance (approximately 150kOhms) minimizing the loading of the circuit being tested. The output impedance is 50 Ohms allowing low noise coaxial connections to all typical test equipment. The 0.1Hz-10Hz noise band is common for opamp measurements, voltage regulators and voltage references. Many application notes offer schematics of such a filter for test purposes. An engineer’s time is much too valuable to be spent building test equipment. We have created a 4th order high pass and 4th order low pass filter with an optimally flat response and 0dB gain. Additional filters can be cascaded for even sharper cutoff.

  • GOOSE Message Recorder

    TR-61850 - Ametek Power Instruments

    Whether a new or existing installation, AMETEK’s TR61850 adds the capability to easily monitor and record GOOSE messages within the substation. All data from the fault recorders and TR61850 automatically merge providing a single point of reference when analyzing transient events and system disturbances. With a wide range of time synchronization, communication options and small form factor, the TR61850 seamlessly integrates into any application.Configuration of the GOOSE Message subscriptions is quick and easy with AMETEK’s configuration tool. Using the IEC61850 Substation Configuration Language (SCL), third party IED Capability Description (ICD) files are imported and subscriptions are created by simply dragging and dropping available GOOSE message outputs.

  • Signal Analyzer

    Anritsu Corporation

    Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.

  • 4K Picture Quality Analyzer

    VP4000 - K-WILL Corp.

    The The frame delay of 2160p full sample 4K reference video and 4K test video are compensated to fit exactly to each other by pixel base, and a real time objective quality score (DSCQS) are calculated by the ITU-T J.144-based assessing method in conjunction with the differential values (PSNR). This scheme is best suited to the encoder evaluation, online/standby comparison, inspection geared to video servers, and so on. For conventional 1080i image evaluation, a single PROBE4000 board can serve the purpose.

  • VXT PXIe Vector Transceiver

    M9421A - Keysight Technologies

    Purpose-built for rapid solution creation and faster throughput in manufacturing test of wireless components, power amplifiers, and RF front-end modules Increase test density and reduce your footprint with up to four VXT instruments in one 18-slot chassis Reduce development time with open-source test libraries and reference solutions Start closer to your finish line with built-in FPGA-accelerated measurements Optimize test routines using proven software for noise figure and standard-specific measurements

  • Fiber Optic Navigation Systems

    SATURN - Teledyne Marine TSS

    SATURN, from Teldyne TSS, is a world leading marine navigation system for surface applications. Built on TSS core fibre optic gyro technology giving unparalleled attitude and heading reference system (AHRS) performance. SATURN offers a fast alignment time of only 10 minutes, from switch-on.It has been designed to address a market need for cost-effective products with competitive specifications for surface use including survey vessels, workboats and commercial shipping vessels. Based on proven FOG technology, and with no moving parts, SATURN is maintenance-free with high MTBF. It is available in three standard heading accuracy variants; 0.1° sec lat (SATURN10), 0.3° sec lat (SATURN30) and 0.5° sec lat (SATURN50).

  • Safety Test Panel for Mixer

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS introduces Safety Test Panel for Domestic Mixer with PC Datalogging. The tests are Performed as Prescribed in IS the Panel Carries out different tests one by one and provides indication of the Test results as OK or NOT-OK. It is very useful and handy in line testing on Mass production line as well as type Testing. Special fixture can be provided for the specific product. This avoids the connections & disconnections of the product for different tests. The total time for entire testing is less than 20 seconds. Micro controller based sequential timer maintains the sequence of operation and displays the test status. This manual contains information about operating instructions and maintenance of the equipment. Please go through this manual carefully and retain it for future reference.

Get Help